Heat Pump Running Cost Calculator

How many kWh will your heat pump use? At a constant COP of 3 with no backup heat, delivering 9,000 kWh of heat takes 3,000 kWh of electricity. Enter your heat demand or operating schedule and electricity rate to estimate annual running cost.

All heat demand, climate-band COPs, prices and costs are user-entered assumptions. Location supplies no weather, tariff or product data. This is not an equipment-sizing or HVAC design tool.

Useful heat reaching the rooms, not purchased fuel or electricity.
Useful thermal output during the equivalent on-hours, not electrical input.
Include duty cycle in these hours or in average output, without counting it twice.
Used to estimate an average heating day, not a weather forecast.
Share of delivered heat, not share of operating hours.
Useful heat / electricity at the same system boundary.
Include your expected defrost/distribution losses; no local weather lookup.
Backup is modelled at COP 1. The remaining heat uses the two compressor bands.
Only additional charges attributable to this scenario.
Constant nominal prices; no replacements or resale.
End-of-year running-cost savings.

About this tool

Estimate heat-pump electricity and operating cost from either known annual useful heat or an average thermal-output schedule. Split compressor heat between milder and colder conditions, add explicit resistance backup, and separate usage charges from annual maintenance, fixed charges and installation cost.

How the calculation works

Schedule heat demand = average useful thermal output x equivalent on-hours per heating day x heating days. Alternatively, use entered annual useful heat. Compressor electricity sums heat in each climate band / its COP; resistance backup uses one kWh electricity per kWh useful heat. Annual running cost = electricity x tariff + annual maintenance + extra fixed charges. Average calendar-month cost = annual running cost / 12. Present cost = installed cost at year zero + discounted year-end running costs.

Worked example

An average 5 kW useful thermal output for 8 equivalent on-hours on 180 heating days supplies 7,200 kWh of heat. Half at COP 4 and half at COP 2 requires 900 + 1,800 = 2,700 kWh electricity. At 0.25/kWh, usage costs 675/year, or 3.75 per average heating day. With 200 maintenance and no extra fixed charge, annual running cost is 875 and the calendar-month average is 72.92. A 10,000 installation plus 15 years of those nominal running costs totals 23,125.

Use useful heat rather than purchased electricity

If you already know heat-pump electricity consumption, the electricity-cost calculator can price it directly. This tool starts from useful heat and estimates electricity through the COP assumptions. Entering purchased electricity as useful heat would apply efficiency a second time and understate cost.

A fuel bill also measures purchased energy rather than useful heat. Apply a defensible delivered-heat efficiency to estimate useful heat before using the annual-demand mode. That efficiency depends on the existing system and the boundary used in your figures.

An average month is not a winter bill

The average calendar-month figure divides annual costs into twelve equal parts. It does not assign demand to actual months. Average heating-day energy divides annual electricity by the number of heating days; its usage charge excludes annual maintenance and fixed charges.

Installation and recurring costs are shown in a separate multi-year table. The present-value figure discounts annual costs at the entered nominal rate. It is a cost measure, so a larger positive value means higher entered discounted expenditure, not greater savings.

Assumptions and limitations

Average thermal output is useful heat, not compressor electrical input or a peak capacity recommendation. Account for cycling in either average output or equivalent on-hours without applying it twice. The climate split represents useful compressor heat; resistance backup is separate. Heating days are an entered allocation assumption, not local weather data.

Actual costs depend on local conditions, room heat loss, equipment capacity, flow temperatures, defrost, distribution, controls and tariffs. HSPF, HSPF2 and SEER are not interchangeable with the dimensionless COP fields. No cooling, hot water, financing, incentive, replacement or residual value is included. Ask a qualified professional for equipment design.

Sources and editorial responsibility

Maintained by Renvoro Pty Ltd. Sources inform the methods and assumptions shown here; outputs have the limitations described on this page.

Guide updated 2026-11-04. Calculation method and source dates remain separate.

Method reviewed 2026-10-21. Calculation standards · Report an issue